When any popup would appear (error, warning, info) the standard digital output channel 0 will be set to HIGH. Program execution gets paused until the event is acknowledged via setting digital input channel 7 to HIGH.

Example 2:

rf_out_state_error=[3, 1]

rf_out_state_warning=[3, 2]

rf_out_state_info=[3, 3]

rf_out_state_code=[5, 1]

rf_out_state_param=[5, 2]

rf_in_state_ack=[3, 1]

Error popups will set boolean output register 1 to True. Warning popups will set boolean output register 2 to True. Info popups will set boolean output register 3 to True. Type of error/warning/info will appear as a unique integer code in integer output register 1. Error specific parameters will appear in integer output register 2. The receiver has to acknowledge the information by setting boolean input register 1 to True.