Skip to end of banner
Go to start of banner

Release Strategy

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 8 Current »

After placing the box on the pallet, you have the option to remove or add waypoints with the release strategy variable.

Code to add in the Callbacks

rf_release_stratagy = “Binary Number”

← Robot movement after placement of the box: (Default Bit=7):

Vertical exit point → Extra waypoint → Smart Exit → Above pickup -->Pickup position

→ Robot movement to place the box on a pallet:

Pickup position → Box free height → Smart Exit → Extra waypoint → Approach Position → Target Position

Binary Number

Description

1

Removes box free height waypoint

2

Removes target position waypoint

4

Add vertical exit after box placement waypoint

8

Removes approach waypoint

16

Removes everything after Smart Exit waypoint

Pally has a default rf_release_strategy=7

That will include

  • Removes box free height (1)

  • Remove target position (2)

  • Add vertical exit (4)

Add the numbers together to use several of the option

  • Recommended for regular grippers: 1 + 2 + 4 = 7

  • Recommended for side grippers: 1 + 2 + 8 = 11

  • Recommended for many custom projects: 16, or 1 + 16 = 17

Example

Release strategy 7 added for the hole program

Release strategy 7 added for after specific box

  • No labels